How can I interface RTCM data from two LD6 units to Verify QC using a single LAN connection (Dual beam corrections)? How do I archive data on an LD6? How do I change a beam on an LD6? How do I change the PPP solution when my LD6 is enabled for both Apex and Ultra services? How do I check the GNSS tracking capabilities of my LD6 version 8 or 50? How do I check the IP address of my LD6? How do I check which version of LD6 I have? How do I configure an LD6 to receive RTK corrections? How do I configure LD6 TRINAV Output? How do I configure my LD6 to use the Apex service? How do I configure NMEA Sentences on an LD6 versions 8 or 50? How do I configure NMEA sentences on LD6 versions 101 and 105? How do I correctly shut down a LD6? How do I enable and output a heading from an LD6? How do I enable SBAS on my LD6 IMU? How do I factory reset my LD6 unit? How do I implement a basic LAN interface between an LD6 and my Verify QC computer? (v1.11 or later) How do I interface my antennas to the LD6? How do I manually enter an L-band frequency on the LD6? How do I remove satellites from my LD6 version 8 or 50? How do I set up LD6 Outputs for VQC? How do you load a Verify QC config onto the LD6 while in QC mode? I have just changed beams and my station list is not fully populated- Why is this? What are the serial pin-outs of the LD6? What are the tracking capabilities of my LD6 and what services are available to my unit? What data is available on the LD6 Ethernet ports? What direction is the heading on my LD6? What files should I send for data analysis from a LD6 while running quantum on board? What is the best way to interface Verify QC to my LD6 units? What is the expected latency from one PPS to the NMEA ZDA telegram on the LD6? What is the PPS voltage and pulse width of my LD6? What version of GNSS card is installed in my LD6?

How do I archive data on an LD6?

To archive data on an LD6 you will need a USB memory stick with a minimum of 256mb of free space. Only carry out this procedure whilst not in critical operations as data outputs can become buffered.

Note: Perform an anti-virus scan on any USB memory before inserting into LD6 

  1. Insert USB memory stick into LD6 USB socket
  2. Press Archive Log Files:

    Press Archive Log Files

  3. Wait until process is complete and press Eject all.
  4. The archive will be saved in a folder name LD6Archives, the archive will have a folder named with the date and time of archive:

    The archive will be saved in a folder name LD6Archives, the archive will have a folder named with the date and time of archive

  5. The folder will consist of 3 zipped folders, config, events and logs:

    The folder will consist of 3 zipped folders, config, events and logs

  6. Select Logs, then Veripos, Logs, and Data. Send selected log files for the period which the problem occurred.

    The log filename syntax is YYMMDD_HHMMSS

If possible send data for 3 hours before the problem started and 1 hour after. The log filename syntax is YYMMDD_HHMMSS.