How can I interface RTCM data from two LD6 units to Verify QC using a single LAN connection (Dual beam corrections)? How do I archive data on an LD6? How do I change a beam on an LD6? How do I change the PPP solution when my LD6 is enabled for both Apex and Ultra services? How do I check the GNSS tracking capabilities of my LD6 version 8 or 50? How do I check the IP address of my LD6? How do I check which version of LD6 I have? How do I configure an LD6 to receive RTK corrections? How do I configure LD6 TRINAV Output? How do I configure my LD6 to use the Apex service? How do I configure NMEA Sentences on an LD6 versions 8 or 50? How do I configure NMEA sentences on LD6 versions 101 and 105? How do I correctly shut down a LD6? How do I enable and output a heading from an LD6? How do I enable SBAS on my LD6 IMU? How do I factory reset my LD6 unit? How do I implement a basic LAN interface between an LD6 and my Verify QC computer? (v1.11 or later) How do I interface my antennas to the LD6? How do I manually enter an L-band frequency on the LD6? How do I remove satellites from my LD6 version 8 or 50? How do I set up LD6 Outputs for VQC? How do you load a Verify QC config onto the LD6 while in QC mode? I have just changed beams and my station list is not fully populated- Why is this? What are the serial pin-outs of the LD6? What are the tracking capabilities of my LD6 and what services are available to my unit? What data is available on the LD6 Ethernet ports? What direction is the heading on my LD6? What files should I send for data analysis from a LD6 while running quantum on board? What is the best way to interface Verify QC to my LD6 units? What is the expected latency from one PPS to the NMEA ZDA telegram on the LD6? What is the PPS voltage and pulse width of my LD6? What version of GNSS card is installed in my LD6?

How do I set up LD6 Outputs for VQC?

The following steps help in setting up an LD6 outputs for Verify QC. Note that these steps are only applicable for LD6 versions 8, 50 and 101. If required see How do I tell which version of LD6 I have? 

LD6 Configuration

When the LD6 is running in Verify QC Mode, COM Ports 9 to 14 are assigned to be used for Verify QC. The user must set the desired Baud Rate, Data Bits, Parity, Stop Bits and Protocol prior to configuring the input or output IO Device in Verify QC.

This can be done by navigating from the LD6 home screen to Settings > IO. To do this press the and scroll to desired com port in the list (COM 9 to 14):

press the and scroll to desired com port in the list (COM 9 to 14)

Click Next to display the Select Device page. This should be set to Verify QC and should not be changed later by the user.

Click Next to display the Select Device page

Click Next then select the Line Standard from RS232 or RS422:

Click Next then select the Line Standard from RS232 or RS422:

Click Next then select the Baud, Data, Parity and Stop Bits and then select Finish:

Click Next then select the Baud, Data, Parity and Stop Bits and then select Finish:

A window will appear to confirm the correct settings, if the settings are correct click Yes.

Verify QC Configuration

In Verify QC Config > Position Output, in the Output / IO Device section the user should set the IO Device to LD6 Port:

In Verify QC Config > Position Output, in the Output / IO Device section the user should set the IO Device to LD6 Port

In the Port list there will be predefined ports (LD6 P9 to LD6 P14):

In the Port list there will be predefined ports (LD6 P9 to LD6 P14):

The user should then select the desired Port:

The user should then select the desired Port:

A Com port already in use by Verify QC or another application on the PC will be grayed out in the Port pull down menu.

The Baud rate must match the settings of the device connected to Verify, or the setting required for the output string. Data Bits, Parity and Stop Bits can be changed if the interfaced device does not use the 8 NONE 1 protocol.

CLIENT SOCKET

RTCM and Demodulator Status data can be received from other applications on the network using Client Sockets with the TCP/IP protocol.

RTCM and Demodulator Status data can be received from other applications on the network using Client Sockets with the TCP/IP protocol.

The Client Socket dialogue allows users to enter the IP Address of the device serving out the data and the Port on which the TCP/IP data is present. If the data is coming from the same computer as Verify QC the IP address should be left as localhost. Ports range is between 0 – 65535.