How can I interface RTCM data from two LD6 units to Verify QC using a single LAN connection (Dual beam corrections)? How do I archive data on an LD6? How do I change a beam on an LD6? How do I change the PPP solution when my LD6 is enabled for both Apex and Ultra services? How do I check the GNSS tracking capabilities of my LD6 version 8 or 50? How do I check the IP address of my LD6? How do I check which version of LD6 I have? How do I configure an LD6 to receive RTK corrections? How do I configure LD6 TRINAV Output? How do I configure my LD6 to use the Apex service? How do I configure NMEA Sentences on an LD6 versions 8 or 50? How do I configure NMEA sentences on LD6 versions 101 and 105? How do I correctly shut down a LD6? How do I enable and output a heading from an LD6? How do I enable SBAS on my LD6 IMU? How do I factory reset my LD6 unit? How do I implement a basic LAN interface between an LD6 and my Verify QC computer? (v1.11 or later) How do I interface my antennas to the LD6? How do I manually enter an L-band frequency on the LD6? How do I remove satellites from my LD6 version 8 or 50? How do I set up LD6 Outputs for VQC? How do you load a Verify QC config onto the LD6 while in QC mode? I have just changed beams and my station list is not fully populated- Why is this? What are the serial pin-outs of the LD6? What are the tracking capabilities of my LD6 and what services are available to my unit? What data is available on the LD6 Ethernet ports? What direction is the heading on my LD6? What files should I send for data analysis from a LD6 while running quantum on board? What is the best way to interface Verify QC to my LD6 units? What is the expected latency from one PPS to the NMEA ZDA telegram on the LD6? What is the PPS voltage and pulse width of my LD6? What version of GNSS card is installed in my LD6?

What files should I send for data analysis from a LD6 while running quantum on board?

This article will detail the steps required to archive data from LD6 105 versions while running Quantum on board. 

Archive LD6 data by inserting a clean USB memory stick which is not encrypted on a free USB port on the LD6 and select Archive Log Files once the splash screen appears. Once archiving completed remove memory stick from LD6 after pressing Eject all.

The required files will be stored within an LD6Archive folder, inside this folder the archive folder can be found. The archive folder will be found with date and time stamp of the archive as the name with three zipped folders inside the folder.

To analyse the data Veripos will require files with the extension .alf or .gps file if the software is 105.3.0.11 or later. 

The .alf files can be found by extracting the Logs zipped file and browsing to the file path below.

 \logs\d_DRIVE\Veripos\Logs\Data\Quantum

These .alf files will named with a date and time stamp in format ddmmyy_hhmmss.alf

Veripos will require a minimum of data three hours before the event and one hour after, copy out the required files and provide these to VERIPOS through the method request. 

copy out the required files and provide these to Veripos through the method request

In case of the 105.3.0.11 or later software, The .gps file can be found under  \logs\d_DRIVE\Veripos\Logs\Data\

The .gps file can be found under  \logs\d_DRIVE\Veripos\Logs\Data\